1. If you are modeling incompressible flow, the pressure drop will be the quantity of interest and not the actual pressure value.

2. Fluent will fix the pressure at a particular location based on either the value at a pressure boundary or the location specified in Operating condition panel. Hence, it is possible to get negative pressure value for an incompressible flow problem.

3. Please check the results of steady state solution for pressure distribution. If the pressure distribution is quite different from the value you obtained after time step-1, please recheck the changes you have made while shifting from steady state to transient state simulation.